HOME
HUMIDISOFT
HEATER SOFTWARE
ACTUATOR SOFTWARE
VALVE SOFTWARE
HVAC Controls
Actuators
Actuated Valves
Humidifiers
Heaters
Careers
Contact Us
Others
Français
Control Panel
How to Use
How to use the SKE4 control panel in order to access the different menu levels and configure the humidifier
Control Profile
External Analog
How to wire and configure a Neptronic HRO20 humidity controller with a SKE4 humidifier
External Network
How to configure a SKE4 humidifier to the network control modes for communication via BACnet or Modbus
Internal Analog
How to configure the SKE4 humidifier as an internal setpoint control using a remote transmitter
Features and Components
Safety Controls
How to use an airflow switch, high limit switch and interlock as safety controls for the SKE4 humidifier
Klixon Thermal Cutout
This video describes the operation of the thermal cutout swtich for the SKE4 humidifier, as well as its associated alarm
Automatic Fill Valve
This video describes the opreration of the 3-way valve used to fill the water in the evaporation chamber and cool down the drain for the SKE4 humidifier
Solid-State Relay
This video describes the operation of the solid-state relay and the SCR control
Configuration Settings
Drain Cycles
How to set the frequency of drain cycle on the SKE4 humidifier
Blowdown Rate
How to configure the blowdown rate or water dilute setting on a SKE4 humidifier
Lowering Steam Output
How to limite the steam capacity of a SKE4 modulating humidifier
Service and Maintenance
Service and Operating Hours
This video is about viewing the number of operating hours and the number of hours of the last servicing on a SKE4 humidifier as well as how to configure the service intervals
Resetting Service Hours
How to reset the service counter after perfoming maintenance of the SKE4 humidifier
Maintenance Procedure
In this video, you will see how to perform maintenance and clean the evaporation chamber on a SKE4 humidifier
Troubleshooting and Alarms
Water Level
What to do if the WaterLevel alarm appears on the SKE4 humidifier
Blocked Piping
What to do if the BlockedPiping alarm appears on the SKE4 humidifier
Failed Pump
What to do if the FailedPump alarm appears on the SKE4 humidifier
Contactor Fuse
What to do if the ContactorsFuse alarm appears on the SKE4 humidifier
Fill Timeout
What to do if the FillTimeout alarm appears on the SKE4 humidifier
Heat Timeout
What to do if the HeatTimeout alarm appears on the SKE4 humidifier
Overheat
What to do if the Overheat alarm appears on the SKE4 humidifier
Water Temperature
What to do if the WaterTemp alarm appears on the SKE4 humidifier